Basic InfoModel NO.: PM-70Type: Patient/Fetal/Maternal MonitorTrademark: ContecOrigin: ChinaClassification: Physiological Functions of Diagnosis and Monitoring EquipmentParameters: ECG, SpO2, NIBP Pulse RateSpecification: ECG, SpO2, NIBP Pulse RateHS Code: 90181930Product DescriptionIntroductionPM70 Patient Monitorcan be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc. FeaturesAll-round monitoring for adult, pediatric and neonatal. 3.5'' (320× 240) TFT LCD. Operate with button and touch screen. Review of data list and trend graph. Configuring interface as user's requirements. Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set. Built-in rechargeable Li-polymer battery for uninterrupted monitoring. PerformanceECG3-lead and 5-lead are optional. Waveform display: Dual-lead/full-leadGain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mVMeasurement range for Heart rate(HR): 30bpm~300bpm, error: ± 1bpm or ± 1%, whichever is greater. Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpmInput current: ≤ 0.1μ AEnduring polarization voltage: ± 300mV, sensitivity range: ± 5%. CMRR: Filter mode(surgery, monitoring)≥ 80dBFrequency response: 1~75Hz(+0.4dB, -3dB)Low-frequency characteristic: Time constant≥ 3.2sAnalysis function: Heart rate, arrhythmia analysis, S-T segment analysisS-T segment range: -2.0mV~2.0mVBlood PressureMeasurement method: OscillometryMeasurement mode: Manual/auto/continuous. Auto measurement interval: Adjustable from 1 to 90 minutes. Resolution: 1mmHg. Accuracy: Maximum Mean deviation≤ ± 5mmHg, Maximum Standard deviation≤ 8mmHg. Self-check function. Overpressure protection: Double protection for software and hardware. 1) RangeAdult: Systolic pressure: 40mmHg~270mmHgMean pressure: 20mmHg~235mmHgDiastolic Pressure: 10mmHg~215mmHgPediatric: Systolic pressure: 40mmHg~200mmHgMean pressure: 20mmHg~165mmHgDiastolic Pressure: 10mmHg~150mmHgNeonatal: Systolic pressure: 40mmHg~135mmHgMean pressure: 20mmHg~110mmHgDiastolic Pressure: 10mmHg~100mmHg2) Upper and lower limit of alarmAdult: Systolic pressure: 40mmHg~270mmHgMean pressure: 20mmHg~235mmHgDiastolic Pressure: 10mmHg~215mmHgPediatric: Systolic pressure: 40mmHg~200mmHgMean pressure: 20mmHg~165mmHgDiastolic Pressure: 10mmHg~150mmHgNeonatal: Systolic pressure: 40mmHg~135mmHgMean pressure: 20mmHg~110mmHgDiastolic Pressure: 10mmHg~100mmHgSpO2 monitoringContinuous real-time measuring. Adopt digital SpO2 technology, which has strong anti-interference capability. Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph. Trend graph with the function of adaptive scalingStandard finger-clip probe for adult, binding probe for neonatal is optional. 1) SpO2MeasuringRange: 35%~100% (Resolution: 1%)Accuracy: ± 2% in stage of 70%-100%, and unspecified in stage of less than 70%. 2) Pulse RateMeasuringRange: 30bpm~250bpm(Resolution: 1bpm)Accuracy: ± 2bpm or ± 2%, whichever is greater. 3) Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ± 4%; The Pulse rate error is ± 2bpm or ± 2%, whichever is greater. 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%. AccessoriesA power adapterAn ECG lead wireA SpO2 probeAn adult NIBP cuffA base of the PM70
Performance Specifications
Display:
3.5" Color TFT
Resolution:
320x240
Display Mode:
Standard face, Waveform face
Indicator:
Power indicator light, Alarm sound, Pluse tone
Interface:
Socket for connecting sensors and sockets for communication cables
Power Supply:
DC 5V, < 300mA
Battery:
Builtin Li-Polymer, 2 hours for charging, 3 hours for continous working. 8 hours for standby mode
Trend Graph:
Resolution from 1s, 5s, 10s. Maximum time 96 hours.
Trend Table:
Resolution from 1s, 5s, 10s. Review up to 1000 items.
Alarm:
Ajustable High and Low limits. Three level audible and vistual alarm
User Configuration:
All the color of parameters and waves can be set according to user' s willing
Technical specifications:
Safety
Meet the requirment of IEC60601 series
Type of Protection:
Class II with internal electirc power supply
Degree of Protection:
BF
Dimention and Weight
Dimention:
145(W)x95(H)x37(D)mm
Weight:
400g(with battery)
Operation Environment:
Temperature: 0~ +40
Humidity: 15% ~ 95%
Storage Environment:
Temperature: -20~ +60
Humidity: 10% ~ 95%
Patient Range
Neonate, Pediatric and Adult
SpO2:
Measurement Range:
0 ~ 100%
Resolution:
1%
Accuracy:
± 2%(70%~100%, Adult/Pediatric, non-motion)
± 3%(70%~100%, Neonate, non-motion)
0% ~ 69% unspecified
Alarm Range:
0% ~ 100%
Refreshing Rate:
1s
Pulse Rate:
Measurement Range:
25 ~ 250 bpm
Resolution:
1bpm
Accuracy:
± 3 bpm (non-motion)
Alarm Range:
25 ~ 250 BMP
Refreshing Rate:
1s
NIBP:
Method:
Oscillometry
Mode:
Manual/Auto/Contiuous
Measurement Range:
25 ~ 260mmHg
Atuo Measure Interval:
5, 10, 15, 30, 45, 60, 90 Minutes
Resolution:
1mmHg
Overpressure Protection:
300mmHg
Alarm range:
25 ~260mmHg KING FINE INDUSTRIAL LIMITED ADD:3F,1 BUILDING,CHUANGYE INDUSTRIAL ZONE, BAISHIXIA, FUYONG,BAOAN DISTRICT,SHENZHEN CITY,CHINA TELL: 0086-755-61559262 FAX:0086-755-61559260 mobile :86018603078063 EMAIL:pengjun0723@163.comwww.screenprotector-china.com |