Patient Monitor with VGA and touch screen

patient monitor with vga and touch screen suppliers, manufacturers China, factory China, made in China, customized, high

Product No.
Product Prices Negotiable
Minimum Order Negotiable
Delivery Days 30 day
INQUIRY
Basic InfoModel NO.: PM-70Type: Patient/Fetal/Maternal MonitorTrademark: ContecOrigin: ChinaClassification: Physiological Functions of Diagnosis and Monitoring EquipmentParameters: ECG, SpO2, NIBP Pulse RateSpecification: ECG, SpO2, NIBP Pulse RateHS Code: 90181930Product DescriptionIntroductionPM70 Patient Monitorcan be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc. FeaturesAll-round monitoring for adult, pediatric and neonatal. 3.5'' (320× 240) TFT LCD. Operate with button and touch screen. Review of data list and trend graph. Configuring interface as user's requirements. Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set. Built-in rechargeable Li-polymer battery for uninterrupted monitoring. PerformanceECG3-lead and 5-lead are optional. Waveform display: Dual-lead/full-leadGain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mVMeasurement range for Heart rate(HR): 30bpm~300bpm, error: ± 1bpm or ± 1%, whichever is greater. Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpmInput current: ≤ 0.1μ AEnduring polarization voltage: ± 300mV, sensitivity range: ± 5%. CMRR: Filter mode(surgery, monitoring)≥ 80dBFrequency response: 1~75Hz(+0.4dB, -3dB)Low-frequency characteristic: Time constant≥ 3.2sAnalysis function: Heart rate, arrhythmia analysis, S-T segment analysisS-T segment range: -2.0mV~2.0mVBlood PressureMeasurement method: OscillometryMeasurement mode: Manual/auto/continuous. Auto measurement interval: Adjustable from 1 to 90 minutes. Resolution: 1mmHg. Accuracy: Maximum Mean deviation≤ ± 5mmHg, Maximum Standard deviation≤ 8mmHg. Self-check function. Overpressure protection: Double protection for software and hardware. 1) RangeAdult: Systolic pressure: 40mmHg~270mmHgMean pressure: 20mmHg~235mmHgDiastolic Pressure: 10mmHg~215mmHgPediatric: Systolic pressure: 40mmHg~200mmHgMean pressure: 20mmHg~165mmHgDiastolic Pressure: 10mmHg~150mmHgNeonatal: Systolic pressure: 40mmHg~135mmHgMean pressure: 20mmHg~110mmHgDiastolic Pressure: 10mmHg~100mmHg2) Upper and lower limit of alarmAdult: Systolic pressure: 40mmHg~270mmHgMean pressure: 20mmHg~235mmHgDiastolic Pressure: 10mmHg~215mmHgPediatric: Systolic pressure: 40mmHg~200mmHgMean pressure: 20mmHg~165mmHgDiastolic Pressure: 10mmHg~150mmHgNeonatal: Systolic pressure: 40mmHg~135mmHgMean pressure: 20mmHg~110mmHgDiastolic Pressure: 10mmHg~100mmHgSpO2 monitoringContinuous real-time measuring. Adopt digital SpO2 technology, which has strong anti-interference capability. Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph. Trend graph with the function of adaptive scalingStandard finger-clip probe for adult, binding probe for neonatal is optional. 1) SpO2MeasuringRange: 35%~100% (Resolution: 1%)Accuracy: ± 2% in stage of 70%-100%, and unspecified in stage of less than 70%. 2) Pulse RateMeasuringRange: 30bpm~250bpm(Resolution: 1bpm)Accuracy: ± 2bpm or ± 2%, whichever is greater. 3) Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ± 4%; The Pulse rate error is ± 2bpm or ± 2%, whichever is greater. 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%. AccessoriesA power adapterAn ECG lead wireA SpO2 probeAn adult NIBP cuffA base of the PM70 Performance  Specifications   Display:   3.5"   Color  TFT Resolution:   320x240 Display  Mode:   Standard  face,   Waveform  face Indicator:   Power  indicator  light,   Alarm  sound,   Pluse  tone Interface:   Socket  for  connecting  sensors  and  sockets  for  communication  cables Power  Supply:   DC  5V,   < 300mA Battery: Builtin  Li-Polymer,   2  hours  for  charging,   3  hours  for  continous  working.   8  hours  for  standby  mode Trend  Graph:   Resolution  from  1s,   5s,   10s.   Maximum  time  96  hours. Trend  Table:   Resolution  from  1s,   5s,   10s.   Review  up  to  1000  items. Alarm:   Ajustable  High  and  Low  limits.   Three  level  audible  and  vistual  alarm User  Configuration:   All  the  color  of  parameters  and  waves  can  be  set  according  to  user' s  willing     Technical  specifications:   Safety Meet  the  requirment  of  IEC60601  series Type  of  Protection: Class  II  with  internal  electirc  power  supply Degree  of  Protection: BF     Dimention  and  Weight   Dimention:   145(W)x95(H)x37(D)mm Weight:   400g(with  battery)     Operation  Environment: Temperature:   0~  +40   Humidity:   15%  ~  95% Storage  Environment: Temperature:   -20~  +60   Humidity:   10%  ~  95% Patient  Range Neonate,   Pediatric  and  Adult     SpO2:   Measurement  Range:   0  ~  100% Resolution:   1% Accuracy:   ±   2%(70%~100%,   Adult/Pediatric,   non-motion)   ±   3%(70%~100%,   Neonate,   non-motion)   0%  ~  69%  unspecified Alarm  Range:   0%  ~  100% Refreshing  Rate:   1s     Pulse  Rate:   Measurement  Range:   25  ~  250  bpm Resolution: 1bpm Accuracy:   ±   3  bpm  (non-motion) Alarm  Range:   25  ~  250  BMP Refreshing  Rate: 1s     NIBP:   Method:   Oscillometry Mode:   Manual/Auto/Contiuous Measurement  Range:   25  ~  260mmHg Atuo  Measure  Interval: 5,   10,   15,   30,   45,   60,   90  Minutes Resolution:   1mmHg Overpressure  Protection:   300mmHg Alarm  range: 25  ~260mmHg KING FINE INDUSTRIAL LIMITED                                                             ADD:3F,1 BUILDING,CHUANGYE INDUSTRIAL ZONE, BAISHIXIA, FUYONG,BAOAN DISTRICT,SHENZHEN CITY,CHINA           TELL: 0086-755-61559262   FAX:0086-755-61559260  mobile :86018603078063 EMAIL:pengjun0723@163.comwww.screenprotector-china.com
Go Back
 
Member Services  Forget Password
more  
more  
 
Login | Join | Member Services | Contact us
BysourcesNo.287, Sec. 1, Xiangshang S. Rd., Nantun Dist., Taichung City 408, Taiwan (R.O.C.)
By BySources copyright(c) 2001-2024 . all right reserved.