TDS8000B Digital Sampling Oscilloscope
Features & Benefits
- DC to 70+ GHz Bandwidth*1
- Exceptional Trigger Jitter and Horizontal Timebase Stability
- Modular Architecture
- Up to Eight Channels Acquisition
- High Resolution and Measurement Repeatability
- Comprehensive, Accurate, Automatic Measurement System
- Intuitive User Interface
- Large Display (10.4 in.)
- Microsoft Windows-based Graphical User Interface
- Windows 2000 for enhanced network security
Applications
- Semiconductor Testing
- Impedance and Crosstalk Characterization (using TDR)
- High-speed Digital Data Communications
Probe & Accessories
P6150 |
9 GHz Passive Probe; the probe consists of a very high quality 20 GHz probe tips, plus an extremely flexible SMA cable. For higher frequency performance the 015-0560-00, or some of the accessory cables listed can be used. |
P8018 |
20 GHz Single-Ended TDR Probe. 80A02 module recommended for static protection of the sampling or TDR module. |
P80318 |
18 GHz 100 Ω Differential Impedance TDR Hand Probe. |
80A03 |
Enables the use of two Tektronix P7000 Series TekConnect™ probes on the DSA8200 or 8000 Series sampling oscilloscopes. |
P7513/ P7516 |
13 GHz and 16 GHz TriMode™ Differential probes. Requires 80A03 interface module. |
P7260 |
6 GHz Active FET Probe. Requires 80A03 interface module |
P7350 |
5 GHz Active FET Probe. Requires 80A03 interface module |
P7350SMA |
5 GHz 50 O Differential-to-Single ended Active Probe. Requires 80A03 interface module. Note that the P7380 probes are recommended over the P7350 probes for sampling purposes due to their higher bandwidth and signal fidelity. |
P7380SMA |
8 GHz 50 O Differential-to-Single ended Active Probe. Requires 80A03 interface module. |
MODULES
80A01
|
Pre-scaled Trigger Amplifier. Not required on the DSA8200, CSA8200, or TDS8200 mainframes with their increased sensitivity pre-scalar. The Amplifier enhances pre-scalar sensitivity on the older TDS8000B and CSA8000B mainframes.
|
80A02
|
DSA8200 EOS/ESD Protection Module (1 channel). P8018 TDR probe recommended.
|
82A04
|
Phase Reference Module for low jitter acquisition (with or without trigger). Accepts signals from 2 GHz to 25 GHz (external filter might be required below 8 GHz), or to 60 GHz with Option 60G.
|
80A05
|
Electrical clock recovery module/clock recovery. Applicable to electrical signals and for the 80C12.
|
80A06
|
PatternSync module for 80SJNB jitter analysis package. Programmable divider for creating a trigger pulse from patterns up to 223 in length.
|
80E04
|
SAMPLING MODULE; DUAL,20 GHZ W/TDR ELECTRICAL SAMPLING MODULE
|
80E08
|
REMOTE SAMPLING MODULE; DUAL CHANNEL, 30 GHZ ELECTRICAL WITH TRUE DIFFERENTIAL TDR
|
80E10
|
REMOTE SAMPLING MODULE; DUAL CHANNEL, 50 GHZ ELECTRICAL WITH TRUE DIFFERENTIAL TDR
|
80C07B
|
OPTICAL SAMPLING MODULE; 2.488 GB/S OC48/STM16,2.500 GB/S 2GBE,2.500 GB/S INFINIBAND;2.5 GHZ OPTICAL BANDWIDTH
|
80C08C
|
OPTICAL SAMPLING MODULE; 9.953/10.31 GB/S 10 GBE,10.51875 GB/S 10GFC,10.664 GB/S G.975,10.71 GB/S G.709,11.1 GB/S 10 GBE FEC;10 GHZ OPTICAL BANDWITH
|
80C10B
|
OPTICAL MODULE; 39.813/43.018 GBPS/80 GHZ
|
80C12
|
Broad wavelength (700 to 1650 nm) multi-rate optical sampling module providing 1G, 2G, 4G, and 8G telecom and datacom testing
|